On Mon, Aug 12, 2013 at 12:40 PM, Bobby Burrow <brbur...@gmail.com> wrote: > These work (http://amzn.to/11ZHKc5) for guy wires up to 3/8" and are > easy to find on the web. > > Bobby > > On 8/12/2013 12:17 PM, Andris Bjornson wrote: > > Hi all, > > > > I'm looking for a field expedient (read "not requiring fancy tension > > meters and special equipment") to evaluate whether guy wires on towers > > are undertensioned. > > > > I'm currently deploying a wireless project in Northern Uganda on > > locally fabricated towers. The engineer who built the towers is very > > good, and was able to provide structural calculations for each tower. > > He does very nice work, and by and large I'm very happy with the > > product. > > > > Someone has mentioned a method to me in the past involving plucking > > guy wires and watching the pulse rate....but I didn't get any numbers > > on what's good and what's bad. > > > > Any help greatly appreciated! > > > > Andris > > > > > > > > > > > > _______________________________________________ > Wireless mailing list > Wireless@wispa.org > http://lists.wispa.org/mailman/listinfo/wireless >