Thanks Bob
I guess this calls for some further testing on my behalf. Do you know (or where I can find out) what actions Wix schedules between InstallInitialize (1500) and ProcessComponents (1600)? I have seen that AllocateRegistrySpace gets scheduled at 1550 but have not seen anything else in my msi's and am conscious that there could be a feature than I'm not using that gets scheduled in between. Therefore if I did start using explicit sequence numbers I would know what to avoid. Thanks From: Bob Arnson [mailto:[email protected]] Sent: 26 March 2009 02:20 To: Windows Installer XML toolset developer mailing list Subject: Re: [WiX-devs] LGHT0179 and Duplicate Sequence No's in InstallExecuteSequence Bob Arnson wrote: Short answer: It's undefined. It's considered bad enough that there's an ICE warning but so bad it's an error. Er, "...but not so bad it's an error." -- sig://boB http://joyofsetup.com/ ----------------------------------------------------------------------------------------------------- HBOS plc, Registered in Scotland No. SC218813. Registered Office: The Mound, Edinburgh EH1 1YZ. HBOS plc is a holding company, subsidiaries of which are authorised and regulated by the Financial Services Authority. ==============================================================================
------------------------------------------------------------------------------
_______________________________________________ WiX-devs mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/wix-devs