The only entry I see related to this error is the _SummaryInformation table's
(from the Diff.wixmst) field '11'. Here's the corresponding row entry for that.
<row op="add" sectionId="/" sourceLineNumber="d:\Enlistments\
SP1.QFE_ROLLUP\private\product\setup\wix\patch\server\obj\i386\V3USelCd\Product.msi">
<field>11</field>
<field>2009/11/04 09:36:30</field>
</row>
It looks like this field 11 is PID_LASTPRINTED property which has the timestamp
when the admin image is created. Got this info from
http://msdn.microsoft.com/en-us/library/aa369748(VS.85).aspx. I don't see any
other row in the table with the same field number which is what the error seems
to be suggesting.
So, what I would like to understand is -
1. Since this WIXMST is generated by TORCH.exe, is there a way to skip
generating this field.
2. Is there a way to apply a patch directly to an MSI instead of its admin
image? I am currently using something like below to generate the Release -->
SP1 admin image before generating a DIFF against the updated MSI:
MSIEXEC -a ReleaseProduct.msi -p SP1_Patch.msp
TARGETDIR=C:\Product
Thanks,
Sharat Janapareddy
~ 40269
-----Original Message-----
From: Sharat Janapareddy [mailto:[email protected]]
Sent: Tuesday, November 03, 2009 7:58 PM
To: [email protected]
Subject: [WiX-users] Error generating MSP for multiple SKUs
I am trying to create an SP1 rollup MSP using these steps - Apply the same SP1
patch to both the Eval and Select SKUs of Release version separately, and then
generate the DIFFs by comparing the corresponding updated versions.
I was able to get to the point where we have the transforms (wixmst) but I get
this error while generating the MSP. The problem here is - the error does not
say which WIXMST or WIXOBJ or what file is causing this.
1>errors in directory
1>d:\enlistments\sp1.qfe_rollup\private\product\setup\wix\patch\server
1>d:\enlistments\sp1.qfe_rollup\private\product\setup\wix\patch\server\pyro.exe
: error PYRO0130 : The primary key '11' is duplicated in table
'_SummaryInformation'. Please remove one of the entries or rename a part of
the primary key to avoid the collision.
1>NMAKE : fatal error U1077: 'd:\enlistments\
sp1.qfe_rollup\public\ext\wix\wix3-binaries\pyro.exe' : return code '0x82'
BUILD: NMAKE.EXE /nologo BUILDMSG=Stop. LINKONLY=1 NOPASS0=1 NTTEST= UMTEST=
386=1 failed - rc = 2
Any ideas on what this is talking about? I don't see any "11" in any of the
WIX* files generated during this process.
Thanks,
Sharat Janapareddy
~ 40269
------------------------------------------------------------------------------
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day
trial. Simplify your report design, integration and deployment - and focus on
what you do best, core application coding. Discover what's new with Crystal
Reports now. http://p.sf.net/sfu/bobj-july
_______________________________________________
WiX-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wix-users
------------------------------------------------------------------------------
Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day
trial. Simplify your report design, integration and deployment - and focus on
what you do best, core application coding. Discover what's new with
Crystal Reports now. http://p.sf.net/sfu/bobj-july
_______________________________________________
WiX-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wix-users