I had the same problem. Apparently, "Feature conditions that include
properties set during the UI sequence won’t work as expected." Instead, use
the AddLocal and Remove events.
This should shed some light on the issue:
http://www.joyofsetup.com/2007/05/30/feature-conditions-and-ui/

On Wed, Mar 3, 2010 at 5:11 PM, Alex Wernecke <awerne...@finteq.co.za>wrote:

> Hi,
>
>
>
> I have a problem with a condition that checks a property's value in
> order to set the LEVEL for a FEATURE
>
>
>
> Here is my code
>
>
>
> PROPERTY that is used by the RADIOBUTTONGROUP :
>
>
>
> <Property Id="SETUPNUMBER" Secure="yes" Value="1"></Property>
>
>
>
> I have tried leaving the value out, changing to different etc etc but
> compiler errors occur then...
>
>
>
> FEATURE :
>
>
>
> <Feature Id='Type1_Installation'
>
>               Title='Type1' Description='Installs Files Required for
> Type1 Setup.'
>
>               Level='3000'
>
>               InstallDefault='local'
>
>               >
>
>      <Condition Level="9999">SETUPNUMBER="2"</Condition>
>
>        <ComponentRef Id='Type1Files'/>
>
> </Feature>
>
> <Feature Id='Type2_Installation'
>
>               Title='Type2' Description='Installs Files Required for
> Type2 Setup.'
>
>               Level='1000'
>
>               InstallDefault='local'
>
>               >
>
> </Feature>
>
>
>
> <Feature Id='Type3_Installation'
>
>               Title='Type3' Description='Installs Files Required for
> Type2 Setup.'
>
>               Level='2000'
>
>               InstallDefault='local'></Feature>
>
>
>
>
>
>
>
>
>
> RADIOBUTTONGROUP :
>
>
>
> <Control Type="RadioButtonGroup" Id="Type" Width="160" Height="160"
> X="40" Y="80" Property="SETUPNUMBER">
>
>          <RadioButtonGroup Property="SETUPNUMBER">
>
>            <RadioButton Text="Type1" Height="17" Value="1" Width="50"
> X="0" Y="0"/>
>
>            <RadioButton Text="Type2" Height="17" Value="2" Width="50"
> X="0" Y="25" />
>
>            <RadioButton Text="Type3" Height="17" Value="3" Width="110"
> X="0" Y="50" />
>
>            <RadioButton Text="Type4" Height="17" Value="4" Width="160"
> X="0" Y="120"/>
>
>          </RadioButtonGroup>
>
>        </Control>
>
>
>
> This sets the SETUPNUMBER Properties value to 1,2,3 or 4 depending on
> the selected radiobutton.
>
> I know this working because the following code works properly as
> expected if the property has changed accordingly :
>
>
>
> <Control Id="Next" Type="PushButton" X="236" Y="243" Width="56"
> Height="17" Default="yes" Text="!(loc.WixUINext)">
>
>          <!-Type1-->
>
>          <Publish Event="SetInstallLevel" Value="2000"
> Order="1">SETUPNUMBER="1"</Publish>
>
>          <Publish Event="NewDialog" Value="InstallDirDlg" Order="2">
> SETUPNUMBER="1"</Publish>
>
>          <!--Type2-->
>
>          <Publish Event="SetInstallLevel" Value="3000"
> Order="6">SETUPNUMBER="2"</Publish>
>
>          <Publish Event="NewDialog" Value="InstallDirDlg"
> Order="7">SETUPNUMBER="2"</Publish>
>
>          <!--Type3-->
>
>          <Publish Event="SetInstallLevel" Value="1000"
> Order="5">SETUPNUMBER="3"</Publish>
>
>          <Publish Event="NewDialog" Value="InstallDirDlg"
> Order="7">SETUPNUMBER="3")</Publish>
>
>        </Control>
>
>
>
>
>
> For some reason the property's value that is read by the condition in
> the features section is the same value as the value in the property
> declaration. And not the value of the selected radiobutton?
>
>
>
> How would I get this to work??
>
>
>
> Many thanks,
>
>
>
> Alex
>
>
>
>
> ------------------------------------------------------------------------------
> Download Intel&#174; Parallel Studio Eval
> Try the new software tools for yourself. Speed compiling, find bugs
> proactively, and fine-tune applications for parallel performance.
> See why Intel Parallel Studio got high marks during beta.
> http://p.sf.net/sfu/intel-sw-dev
> _______________________________________________
> WiX-users mailing list
> WiX-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/wix-users
>
------------------------------------------------------------------------------
Download Intel&#174; Parallel Studio Eval
Try the new software tools for yourself. Speed compiling, find bugs
proactively, and fine-tune applications for parallel performance.
See why Intel Parallel Studio got high marks during beta.
http://p.sf.net/sfu/intel-sw-dev
_______________________________________________
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users

Reply via email to