On 26/02/2015 02:35, David Bowman wrote:

Hi David,

> I'm receiving "hamlib: Invalid configuration while opening connection 
> to rig".  I had regular crashes with v 1.3 r 3673 but made many 
> contacts.  My setup is:
>
> Kenwood TS-2000
> poll int = 2 sec
> Com3 for Cat
> rate 38400
> data bits 8
> stop bits one
> force control lines = rts
> ptt method = rts com5
> transmit audio source = front/pkt
> mode = data/pkt
> split operation = none
> TEST CAT color is red
> TEST PTT is grayed out.

That is a known defect that has been repaired for later releases.

Unless you have a CAT interface that draws power from the RS-232 line 
RTS, your configuration is not correct, if you un-check "Force Control 
Lines" "RTS" and check "Handshake" "Hardware" you should be able to 
connect to your rig.

73
Bill
G4WJS.

------------------------------------------------------------------------------