Bill,

In the past couple of hours since updating to r5700 I have had four rig control 
error events after many weeks of flawless operation. “Command rejected by the 
rig while setting frequency” 

After program startup the error has occurred after only 1 and as many as 4 
transmissions.

It looks like Tx Enable is dis-abled when the error is thrown. Thereafter the 
rig stays on whatever band it was on when the error was thrown, but the program 
continues to hop through different bands, causing spots to be reported on the 
wrong band. 

This behavior is completely new to me, and it happened immediately after 
updating to r5700. I’m not sure what revision I was on before the problem 
started, but it was certainly no earlier than r5685. Has anything changed in 
the last few revisions that might affect control of a TS-480? e.g. timing or 
delay changes maybe?

Steve k9an
------------------------------------------------------------------------------