Hi Keith and all,

There is a very good reason why you won't see any example of two nonstandard callsigns working each other in these documents posted on Monday:

http://physics.princeton.edu/pulsar/k1jt/New_Features_WSJT-X_2.0.txt
http://physics.princeton.edu/pulsar/k1jt/77bit.txt

The fully general nonstandard callsign supported in WSJT-X 2.0 required 58 bits. Very obviously, two of these cannot fir into a 77-bit message payload.

        -- 73, Joe, K1JT

On 9/19/2018 4:21 PM, Keith Wallace wrote:
Tried a non standard CQ earlier.

CQ EI100MCV (no locator)

Answered

EI100MCV OM100CSR

*Sent back*

OM100CSR EI100MCV

Auto seq would not progress past this.

Keith
EI5KO