On 02/01/2019 07:18, Michael Tope wrote:
I am a new FT8 user running WSJT-X 2.0. So far I have just been
monitoring the FT8 sub-band on 160 meters (I have not tried
transmitting yet). When I leave WSJT-X 2.0 running for an extended
period, I keep getting the following Subprocess error (Subprocess
failed with exit code 2) when I come back to the computer:
/Running: C:\WSJT\wsjtx\bin\jt9 -s WSJT-X -w 1 -m 3 -e
C:\WSJT\wsjtx\bin -a C:\Users\W4EF\AppData\Local\WSJT-X -t
C:\Users\W4EF\AppData\Local\Temp\WSJT-X
At line 543 of file C:\Users\bill\src\k1jt\wsjtx\lib\decoder.f90
Fortran runtime error: Index '1001' of dimension 1 of array
'c2fox' above upper bound of 1000/
Program Info: WSJT-X v2.0.0 784f75
OS: Windows 7 Home Premium, Service Pack 1
Computer: Dell Vostro 270
Processor: Intel i3-3220
Installed RAM: 4 GB
System Type: 64 bit
Any suggestions would be appreciated.
73, Mike W4EF/6 DM14
Hi Mike,
thanks for the issue report. We are aware of this defect and it has been
fixed for the next release. For now all I can suggest is that you
restart WSJT-X now and again, the error only happens after an extended
period of operation.
73
Bill
G4WJS.