Hi all! Excellent idea! I wish those who call endless CQ on wrong period on 50 MHz would use it.
Maybe: similar approach as TX1/TX2 or RRR/RR73 selection. (double click on Next near TX6) TX6 may be marked as: CQ S52D JN76 (1) CQ S52D JN76 (2) indicating number of periods between two CQs. Pressing F1 or clicking next or ending QSO would start CQ like (1) is selected. Best 73, gl, take care Iztok, S52D
Hello, on a quiet band I find it useful to call CQ every second round (once a minute in FT8). That allows me to monitor both even and odd periods inbetween the CQ's and as the duty cycle is only 25% I can CQ for a long period without overheating the TX. For now I do the manually (via the enable TX button), but if others find this useful as well it might be considered to add it as an option in WSJT-X? 73, Rik ON7YD - OR7T
[https://ts1.sdn.si/mailing/podpis/Bliskoviti_obisk_250x170px_06.jpg] <https://www.telekom.si/zasebni-uporabniki/ponudba/internet/internetne-storitve/bliskoviti-obisk?utm_source=mail_podpis&utm_medium=mail_podpis&utm_campaign=mail_podpis> Pravni pogoji / Legal disclaimer Telekom Slovenije, d.d., Ljubljana <http://www.telekom.si/disclaimer> _______________________________________________ wsjt-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/wsjt-devel