Hi Artie and Norbert,
thanks for the issue reports. We are working on this right now, it will
be fixed for the next release.
73
Bill
G4WJS.
On 31/05/2020 00:25, Artie Langston wrote:
Exact same issue observed here with Windows 10, IC-7300.
Installed rc3, split worked perfectly on 15M, switched bands to 6M,
split frequency of 21.075.50 stuck in VFO B forever. Rig turned off,
power supply off, program closed, when everything is turned back on,
21.075.50 is still stuck in VFO B, no matter what band is selected.
"Fake it" still works.
Artie KD0GY
On Sat, May 30, 2020 at 4:56 PM Norbert Graf - DD3KF <i...@dd3kf.de
<mailto:i...@dd3kf.de>> wrote:
Hello Joe, Bill and Steve,
TU for the new RC3.
Win 10/64, WSJT-X 64 bit RC3
SPLIT OPERATION:
The ICOM 7300 still did not work properly with "RIG". Went back to
FAKE IT.
The
- IC 7610,
- IC 9700
working now okay on RIG.
73
_______________________________________________