> On Sep 18, 2022, at 22:32, Reino Talarmo via wsjt-devel
> <wsjt-devel@lists.sourceforge.net> wrote:
>
> This may be irrelevant, but how you returned from FT4 to FT8 to work the
> single station?
>
>> When I tried to restart WSJT-X, it failed, giving me the following error:
> Sub Process Error
> Failed to close orphaned jt9 process
>
> The failure reason is solely due to the orphaned jt9 (jt8.exe) process that
> is the main engine for decoding within wsjt-x, I think. You could have also
> kill the process (jt8.exe) using Windows Task Manager. Normally that is
> enough and no need to reboot the total system.
Will try to remember that, but I will be surprised if it happens again. ;-)
Gary - AG0N