Program Version: WSJT-X Improved v2.8.0 250501OS: Arch Linux Problem: When using, "Rig: Hamlib NET rigctl" to connect to rigctld daemon for the FT-736R, WSJT-X bails out when rig_get_mode returns -11 for CAT control.
The FT-736R is essentially write-only for CAT control and doesn't support being asked what modes it supports. I have set mode to None, but WSJTX still insists on querying the mode. If I use telnet to connect to the rigctld daemon, I can PTT and set frequencies just fine. If I set WSJT-X to use the FT-736R directly, everything works just fine with no hamlib errors, but modes don't work (as expected). Ideally, if none is set for mode, the existing mode shouldn't be queried either. Thanks, Logan
publickey - iqw1345@proton.me - 0x1B9DD33D.asc
Description: application/pgp-keys
signature.asc
Description: OpenPGP digital signature
_______________________________________________ wsjt-devel mailing list wsjt-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wsjt-devel