Program Version: WSJT-X Improved v2.8.0 250501OS: Arch Linux

Problem: When using, "Rig: Hamlib NET rigctl" to connect to rigctld daemon for 
the FT-736R, WSJT-X bails out when rig_get_mode returns -11 for CAT control.

The FT-736R is essentially write-only for CAT control and doesn't support being 
asked what modes it supports. I have set mode to None, but WSJTX still insists 
on querying the mode. If I use telnet to connect to the rigctld daemon, I can 
PTT and set frequencies just fine.

If I set WSJT-X to use the FT-736R directly, everything works just fine with no 
hamlib errors, but modes don't work (as expected).

Ideally, if none is set for mode, the existing mode shouldn't be queried either.

Thanks,
Logan

Attachment: publickey - iqw1345@proton.me - 0x1B9DD33D.asc
Description: application/pgp-keys

Attachment: signature.asc
Description: OpenPGP digital signature

_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to