On Tue, Oct 28, 2008 at 10:41:33AM -0500, we recorded a bogon-computron collision of the <[EMAIL PROTECTED]> flavor, containing: > I have a definition in my Interface Control set up to talk to my > KPC3+. I mistakenly assumed that the disconnect side of it would be; > tnc-stop.kpc3 similar to its startup of tnc-startup.kpc3 but its not > that and now I can't stop the interface.
Bleah. That's bad --- xastir should complain when there is no file matching the name given, not hang like this. But there is no tnc-stop.kpc3, so that's the issue. > In fact if I try to stop it Xastir freezes and won't quit, I have to > kill it. When I restart Xastir it still shows this interface as 'UP' > and nothing will make it stop. I also tried editing the properties to > change the it to tnc-stop.sys but it only causes Xastir to freeze up > again, any kind of edit here causes it to freeze. > > I'm guessing there is someplace in a configuration file that I could > delete this interface from but I don't know where, can someone help me > here? Yep. Just edit the file "~/.xastir/config/xastir.cnf" with your favorite plain-text editor (vi/emacs/nano/pico or whatever) and remove the reference to tnc-stop.kpc3. Should not be hard to find. It'll be on a line labeled "DEVICEn-TNC_DOWN-FILE" with "n" being the device number. You can replace it with "tnc-stop.sys" instead, which is a generic stop file that'll work fine with the KPC3+. -- Tom Russo KM5VY SAR502 DM64ux http://www.swcp.com/~russo/ Tijeras, NM QRPL#1592 K2#398 SOC#236 AHTB#1 http://kevan.org/brain.cgi?DDTNM "Argue for your limitations and sure enough, they're yours." -- R. Bach _______________________________________________ Xastir mailing list Xastir@xastir.org http://lists.xastir.org/cgi-bin/mailman/listinfo/xastir