>>> On 26.02.16 at 05:37, <kevin.t...@intel.com> wrote:
>>  From: Zhang, Haozhong
>> Sent: Tuesday, February 23, 2016 10:05 AM
>> 
>> Signed-off-by: Haozhong Zhang <haozhong.zh...@intel.com>
> 
> Reviewed-by: Kevin Tian <kevin.t...@intel.com>, except:
> 
>> +
>> +Hardware TSC Scaling
>> +
>> +Intel VMX TSC scaling and AMD SVM TSC ratio allow the guest TSC read
>> +by guest rdtsc/p increasing in a different frequency than the host
>> +TSC frequency.
>> +
>> +If a HVM container in default TSC mode (tsc_mode=0) or PVRDTSCP mode
> 
> 'HVM container' means something different. We usually use "HVM domain"
> as you may see in other places in this doc.

But I think this is specifically meant to refer to both HVM and PVH
domains.

Jan


_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xen.org
http://lists.xen.org/xen-devel

Reply via email to