Trying to add an offline cpu to a cpupool can crash the hypervisor,
as the probably non-existing percpu area of the cpu is accessed before
the availability of the cpu is being tested. This can happen in case
the cpupool's granularity is "core" or "socket".

Fix that by testing the cpu to be online.

Fixes: cb563d7665f2 ("xen/sched: support core scheduling for moving cpus 
to/from cpupools")
Reported-by: René Winther Højgaard <rene...@proton.me>
Signed-off-by: Juergen Gross <jgr...@suse.com>
---
V2:
- enhance commit message
---
 xen/common/sched/cpupool.c | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/xen/common/sched/cpupool.c b/xen/common/sched/cpupool.c
index 2e094b0cfa..ad8f608462 100644
--- a/xen/common/sched/cpupool.c
+++ b/xen/common/sched/cpupool.c
@@ -892,6 +892,8 @@ int cpupool_do_sysctl(struct xen_sysctl_cpupool_op *op)
         if ( cpu >= nr_cpu_ids )
             goto addcpu_out;
         ret = -ENODEV;
+        if ( !cpu_online(cpu) )
+            goto addcpu_out;
         cpus = sched_get_opt_cpumask(c->gran, cpu);
         if ( !cpumask_subset(cpus, &cpupool_free_cpus) ||
              cpumask_intersects(cpus, &cpupool_locked_cpus) )
-- 
2.35.3