On Fri, May 22, 2020 at 03:42:10PM +0200, Jan Beulich wrote:
> On 21.05.2020 11:22, Roger Pau Monne wrote:
> > Apply a workaround for Intel errata BDX99, CLX30, SKX100, CFW125,
> > BDF104, BDH85, BDM135, KWB131: "A Pending Fixed Interrupt May Be
> > Dispatched Before an Interrupt of The Same Priority Completes".
> 
> While the change looks good to me as far as Broadwell goes, I
> think it was before this posting that Andrew also pointed at
> a specific Haswell erratum instance, still on the v3 thread.
> Am I to imply a v5 will follow adding affected Haswell models
> to the table?

Those refer to a different errata, see:

https://lore.kernel.org/xen-devel/[email protected]/

So we believe this also affects Haswell, but the errata is not published
for those CPUs (yet at least). If/when it's published I'm happy to add
it, in the meantime I think we should go with what has been published
by Intel.

Roger.