On Sun, Nov 01, 2009 at 07:59:56PM +0100, Jens Elkner wrote:
Hi,
  
> just upgraded a machine from snv_b98 to snv_b125. Unfortunately domUs do
> not start anymore:
> 
> # virsh start win2008ss
> error: Failed to start domain win2008ss
> error: POST operation failed: xend_post: error from xen daemon:
> (xend.err 'signed integer is greater than maximum')

Problem solved by re-defining all domains, i.e.
virsh dumpxml $domain >/tmp/$domain
virsh undefine $domain
virsh define /tmp/$domain

Adding an appropriate note to the wiki (e.g.
http://hub.opensolaris.org/bin/view/Community+Group+xen/SolarisAsGuestHost )
might be a good idea ...

Regards,
jel.
-- 