On Sun, Nov 01, 2009 at 07:59:56PM +0100, Jens Elkner wrote: Hi, > just upgraded a machine from snv_b98 to snv_b125. Unfortunately domUs do > not start anymore: > > # virsh start win2008ss > error: Failed to start domain win2008ss > error: POST operation failed: xend_post: error from xen daemon: > (xend.err 'signed integer is greater than maximum')
Problem solved by re-defining all domains, i.e. virsh dumpxml $domain >/tmp/$domain virsh undefine $domain virsh define /tmp/$domain Adding an appropriate note to the wiki (e.g. http://hub.opensolaris.org/bin/view/Community+Group+xen/SolarisAsGuestHost ) might be a good idea ... Regards, jel. -- Otto-von-Guericke University http://www.cs.uni-magdeburg.de/ Department of Computer Science Geb. 29 R 027, Universitaetsplatz 2 39106 Magdeburg, Germany Tel: +49 391 67 12768 _______________________________________________ xen-discuss mailing list [email protected]