Hello Mehdi--

>
> Thank you for your reply; Actually one of output options of  SPARKY is XEASY
> format, how can I convert the xeasy format (chemical shift list and peak
> list) to the readable format by XPLOR or PASD?MARVIN facility?
>

xeasy should be directly readble by PASD. In your initMatch TCL
script, place a

package require xeasy

at the top

and then use process3dXeasyPeakTable

Shift tables must be in nmrstar or pipp format. If there is an xeasy
shift format I will gladly add that.

best regards--
Charles