Hi Charles,

I applied the modification you mentioned in  last email, I also converted the 
XEASY shift list (.prot file)  to pipp by dataconverter on BMRB site, however 
when I run the script "initMatch TCL" there is error message:

"Missing required flag -fromHeavyatomColumnName
Neither -pot nor -shiftAssignments defined in call to recordUnfoldedPositions"

Do you have any idea what the problem would be?

Thank you very much

Mehdi



________________________________
 From: Charles Schwieters <[email protected]>
To: Mehdi Talebzadeh Farooji <[email protected]> 
Cc: "[email protected]" <[email protected]> 
Sent: Tuesday, February 28, 2012 5:30:04 PM
Subject: Re: [Xplor-nih] Xeasy to xplor format
 

Hello Mehdi--

>
> Thank you for your reply; Actually one of output options of  SPARKY is XEASY
> format, how can I convert the xeasy format (chemical shift list and peak
> list) to the readable format by XPLOR or PASD?MARVIN facility?
>

xeasy should be directly readble by PASD. In your initMatch TCL
script, place a

package require xeasy

at the top

and then use process3dXeasyPeakTable

Shift tables must be in nmrstar or pipp format. If there is an xeasy
shift format I will gladly add that.

best regards--
Charles


--
Charles Schwieters     email:  [email protected]
                       www:    http://schwieters.org/cds
phone: (301) 402-4914  PGP key: http://schwieters.org/cds/pgp.txt
_______________________________________________
Xplor-nih mailing list
[email protected]
http://dcb.cit.nih.gov/mailman/listinfo/xplor-nih

Reply via email to