Hello Marcel--

> I have been using the steric alignment RDC potential (as in
> /eginput/sardc/) for structural refinement, recently. It worked just
> like the example and I got nicely refined structural
> ensembles. However, I am currently trying to use the same set-up on
> a dimeric X-ray structure with segids A and B. Every time Xplor
> tries to evaluate my RDC file for this dimer I receive the below
> pasted error message. I assumed that it has something to do with an
> improper RDC restraint file, so I tested different ways of atom
> selection but to no avail.
>
> Originally:  assign (resid  103 and name HN) (resid  103 and name  N) 3.440 
> 0.105 0.000 1.023 0
> Variant 1:  assign (resid  103 and name HN and segid A) (resid  103 and name  
> N and segid A) 3.440 0.105 0.000 1.023 0
> Variant 2:  assign (resid  103 and name HN and (segid A or segid B)) (resid  
> 103 and name  N and (segid A or segid B)) 3.440 0.105 0.000 1.023 0
>

For 2.30 you'll want to use variant 1. Variant 2 (equivalent to
omitting the segid specification) will be supported in the next release.

>
> I can't make too much of the error message so any help is gratefully
> acknowledged.
>
>
>   File "/opt/xplor-nih-2.29/python/trace.py", line 180, in run

Please try upgrading to Xplor-NIH version 2.30, as we did fix some
issues along these lines.

> SystemError: xplor-nih error: Error: named selection with name
> pseudo contains an inconsistent number of atoms.

If the upgrade fails, please let me know. Another possible workaround
might be to put a

protocol.updatePseudoAtoms()

before the call to create_SARDCPot.

best regards--
Charles
--
Charles Schwieters     email:   [email protected]
                       www:     http://schwieters.org/cds
phone: (301) 402-4914  PGP key: http://schwieters.org/cds/pgp.txt

Attachment: pgp2fCg3fSoCZ.pgp
Description: PGP signature

_______________________________________________
Xplor-nih mailing list
[email protected]
http://dcb.cit.nih.gov/mailman/listinfo/xplor-nih

Reply via email to