Hello Marie-Laurence--

> 
> Our lab recently switched from XPLOR-NIH version 2.19 to version
> 2.33.  It would seem that the former proton stereospecificity (HD**
> or HG**) in the NOE restraint files have changed to only accept HD(1
> or 2)* or HG(1 or 2)*.

I apologize. This is a bug- it will be fixed in the next
release. However, you should be able to use simply HD* or HG* in this
case.

> My methyl protons aren't stereospecifically assigned and I was
> wondering how XPLOR is treating those proton and how we keep the
> ambiguity?

sum averaging is usually used, which usually effectively picks out the
shortest distance. 

> Do we have to use the potential
> described in:
> 
> Kuszewski, J., Gronenborn, A.M. & Clore, G.M. (1996) A potential
> involving multiple proton chemical shift restraints for
> non-stereospecifically assigned methyl and methylene
> protons. J. Magn. Reson. Series B 112, 79-81 

That algorithm is not implemented for distance restraints, and I'm not
convinced it will work particularly well. Sum averaging is probably a
better bet.

best regards--
Charles
--
Charles Schwieters     email:   [email protected]
                       www:     http://schwieters.org/cds
phone: (301) 402-4914  PGP key: http://schwieters.org/cds/pgp.txt

Attachment: pgp37s1gaDtmf.pgp
Description: PGP signature