Hello Leah--

>
> I am using TEMPO as a spin labeled to acquire PRE data to get
> distance restraints but I am not finding a TEMPO library in
> Xplor-nih, I could only find MTSL.  Is there a TEMPO library?
>

I don't seem to have topology and parameters for TEMPO. You might
check with the Kay lab, as I believe they have used this
tag. Otherwise, I can help you generated the necessary files. Of
course, if anyone else has already generated these, contributing them
would be greatly appreciated.

best regards--
Charles
--
Charles Schwieters     email:   [email protected]
                       www:     http://schwieters.org/cds
phone: (301) 402-4914  PGP key: http://schwieters.org/cds/pgp.txt