Bruno Chareyre a écrit :
> Hello
>
> Elastic contact law is broken in the default TriaxialTest. I guess it is
> linked with r1822.
> It looks like friction is almost inactive ("almost" because shearForce
> is not null when I look into a xml, but the sample still has a
> negligible shear strength).
>
> Not clear for me :
>
> -What is the result of "#ifdef SCG_SHEAR" by default?
> -TriaxialTest generates a contact law with useShear=0 by default, is
> that correct? When I put useShear=1, the result looks better.
> -momentRotationLaw="1" by default, is that correct? (it has always been
> that way perhaps, if nobody opposes, i'll set it false by default)
According to me momentRotationLaw="1" by default is not correct but I
understood, that until now, this booleen is not used... Ok for
momentRotationLaw="0"
> -Could we please keep the old version of this contact law by default?
Ok for me
Luc
>
> Bruno
>
--
Luc Sibille
Université de Nantes - Laboratoire GeM UMR CNRS
IUT de Saint Nazaire
58, rue Michel-Ange - BP 420
44606 Saint-Nazaire Cedex, France
Tel: +33 (0)2 40 17 81 78
_______________________________________________
Mailing list: https://launchpad.net/~yade-users
Post to : [email protected]
Unsubscribe : https://launchpad.net/~yade-users
More help : https://help.launchpad.net/ListHelp
_______________________________________________
yade-users mailing list
[email protected]
https://lists.berlios.de/mailman/listinfo/yade-users