wangxiaoliang posted a new comment:
>@ luc #9: I guess this should be the title of your question? I also guess that 
>you are using Law2_ScGeom6D_CohFrictPhys_CohesionMoment. Am I right?
Yes you are right. I know comFricDegree and finalFricDegree.

>The triaxial compression is thus performed on a sample with initial porosity 
>equal to 0.40.
actually, in real consolidated drained compression, I prepare my sample with 
the  "initial porosity" 
I want, then add isotropic pressure, say 50kPa. In DEM simulation, many authors 
also mentioned 
"initial porosity" like with the radius-expansion method, so I think 0.40 here 
should be the porosity
after consolidated compared to the real CD compression, am I right? But in real 
experiment, we say
initial porosity, that should be before consolidation

-- 
You received this question notification because you are a member of