Question #210907 on Yade changed: https://answers.launchpad.net/yade/+question/210907
wangxiaoliang posted a new comment: >@ luc #9: I guess this should be the title of your question? I also guess that >you are using Law2_ScGeom6D_CohFrictPhys_CohesionMoment. Am I right? Yes you are right. I know comFricDegree and finalFricDegree. >The triaxial compression is thus performed on a sample with initial porosity >equal to 0.40. actually, in real consolidated drained compression, I prepare my sample with the "initial porosity" I want, then add isotropic pressure, say 50kPa. In DEM simulation, many authors also mentioned "initial porosity" like with the radius-expansion method, so I think 0.40 here should be the porosity after consolidated compared to the real CD compression, am I right? But in real experiment, we say initial porosity, that should be before consolidation -- You received this question notification because you are a member of yade-users, which is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : yade-users@lists.launchpad.net Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp