Question #679050 on Yade changed:
https://answers.launchpad.net/yade/+question/679050

Bruno Chareyre proposed the following answer:
One more option: it could be that timestep is ok wrt both numerical stability 
and velocity vs. diameter, with particles going through the plate due to the 
magnitude of forces.
young = 200e9 sounds stiff but you are speaking of moving 25m of steel with +/- 
3.5m amplitude at a frequency of 60Hz, which is beyond current technology .
Check your units.

-- 
You received this question notification because your team yade-users is
an answer contact for Yade.

_______________________________________________
Mailing list: https://launchpad.net/~yade-users
Post to     : yade-users@lists.launchpad.net
Unsubscribe : https://launchpad.net/~yade-users
More help   : https://help.launchpad.net/ListHelp

Reply via email to