Question #695065 on Yade changed:
https://answers.launchpad.net/yade/+question/695065

    Status: Open => Needs information

Robert Caulk requested more information:
Hello,

Which example script are you referring to? You just point to a commit of
many scripts... Please link to the exact script somewhere in the
examples folder [1].

>When I use a previously compacted, poly-disperse-particle sample for
this analysis, the temperature of all particles remains constant at
first and then turns to "nan".

What exactly are you changing compared to the example script? You are
using a poly-disperse packing instead of a mono-disperse packing? Please
try to say something like "when I change *BLANK* the script works, when
I change *BLANK* the script fails."

-Robert

[1] https://gitlab.com/yade-
dev/trunk/-/tree/master/examples/ThermalEngine

-- 
You received this question notification because your team yade-users is
an answer contact for Yade.

_______________________________________________
Mailing list: https://launchpad.net/~yade-users
Post to     : yade-users@lists.launchpad.net
Unsubscribe : https://launchpad.net/~yade-users
More help   : https://help.launchpad.net/ListHelp

Reply via email to