On Aug 1, 2012, at 7:44 PM, Elvis Dowson <elvis.dow...@gmail.com> wrote:
> Hi Khem, > > On Aug 2, 2012, at 2:37 AM, Khem Raj wrote: > >> On Aug 1, 2012, at 9:18 AM, Elvis Dowson <elvis.dow...@gmail.com> wrote: >> >>> Hi, >>> Perhaps the reason none of my root file system binaries are not working >>> or running is because there is no >>> >>> GLIBCTARGETOS ?= "linux-gnueabi" >>> >>> in my machine/virtex5.conf or local.conf file? >> >> you don't need to set it. it should be automatically computed based on libc >> and arch >> your problem seems more like console related. Probably you don't have >> console params >> set correctly or securetty does not know about your console device. > > You're right. After rebuilding it, with that variable set, it made no > difference in the generated > binaries, (e.g. generate a tool chain powerpc-poky-linux-gnueabi-gcc) nor did > it > change the situation with my having no console login or bash prompt. > > The serial port that I am using is ttyS0. There is an entry for ttyS0 under > /dev in my ramdisk > , and my /etc/device_table also has an entry for ttyS. > > I have also checked that my securetty has an entry for ttyS0. > > I have tried all possible option, e.g. try to get inittab running first with > > S:2345:respawn:/sbin/getty 9600 ttyS0 > > then with > > S:2345:respawn:/bin/sh 9600 ttyS0 well. When I look into virtext configuration then I see SERIAL_CONSOLE ?= "115200 ttyUL0" I wonder if you have tried that configuration for serial console. _______________________________________________ yocto mailing list yocto@yoctoproject.org https://lists.yoctoproject.org/listinfo/yocto