Nevermind...I'm an idiot. It would help if I used the right oids when I put them into zenoss :)
My snmpwalk was using the right OIDs, but for some reason, when I put them into zenoss I put in a different one. --Dennis On Thu, 8 Jun 2006 11:06:53 -0500, Dennis B.Hopp <[EMAIL PROTECTED]> wrote: > > I'm finally really getting to play with zenoss. Nice work on the new > installer by the way... > > I'm having trouble monitoring cisco routers (2600 and 3600 series). The > interfaces get monitored fine, but I can't seem to get the cpu utilization > montiored. > > I've modified the device template to include: > > cpmCPUTotal1min 1.3.6.1.4.1.9.9.109.1.1.1.1.4.0 GAUGE > cpmCPUTotal5min 1.3.6.1.4.1.9.9.109.1.1.1.1.5.0 GAUGE > cpmCPUTotal5sec 1.3.6.1.4.1.9.9.109.1.1.1.1.3.0 GAUGE > > Which if I use snmpwalk those oids return the values I expect, but I get > an event when zenoss tries to poll saying the oid is bad. > > Any ideas? Or is there a better way to do it? > > Thanks, > > --Dennis > > _______________________________________________ > zenoss-users mailing list > [email protected] > http://lists.zenoss.org/mailman/listinfo/zenoss-users _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users