David,
To monitor oids that have indexes we currently need to extend the
model... What we need to do is make it easy to extend the model in
arbitrary ways. That said we do have CPU in the model and I think
the "modern" way to monitor cisco cpus is to basically use a cpu
index correct? I haven't looked at the PROCESS-MIB but it sounds
like its more of a process list then a CPU list...
-EAD
On Dec 20, 2006, at 4:24 PM, David Carmean wrote:
So I've managed to create an RRDTemplate that monitors the deprecated
Cisco avgBusy1, etc, CPU load objects; since this this is a non-
indexed OID,
I can place it in the .../Device RRDTemplate.
However, the more modern CISCO-PROCESS-MIB has a set of indexed
objects such
as cpmCPUTotal1Min. I think I've just learned that the .../Device
RRDTemplates
can't deal with indexed objects; is that correct? And I also want
to add
Cisco environment monitoring, which will also be indexed.
What needs to be done to extend the system to handle (model?) the
additional
Meta Types (?) required to monitor arbitrary indexed objects?
Thanks.
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users