On Apr 1, 2008, at 12:01 AM, daviz00 wrote:
Well after a few long days of studying the Zenoss source I finally documented the method for generating a dynamicly collected view along with a custom modeler plugin.

Basically it collects the outlets for an APC Switched PDU or UPS for short. It adds a custom tab to view the outlets with some handy info such as status (on/off), The phase, bank, device name plugged into the outlet, along with any pending commands per outlet. All of this is using the fancy Zenoss gui and it feels 100% integrated down to the green/red dots for status :)

Should have everything documented and available on my site within about a week or so. Finally have a clear path to modeling just about anything.

I will also provide a Zenpack. I'll upload that sometime tomorrow with documentation for creating your own plugins soon to follow.

I can't wait to see this, Zach! Hopefully this will open the door for many more advanced community ZenPacks.