It uses event mappings... check your sequence numbers for the event mappings. -- James Pulver Information Technology Area Supervisor LEPP Computer Group Cornell University
jujubar wrote, On 5/14/2009 11:51 AM: > I have 2 event classes with patterns shown below, the first of which is a > subset of the second, like: > WARNING CLIENT ABC limit exceeded > and > WARNING.*limit exceeded > > How does zenoss determine which event class to assign an alert that matches > both these patterns to? > I need to do this because some people need to be alerted when an event > matching the first pattern arrives and some other people need to be alerted > when an alert matching the second pattern arrrives. > > > > > -------------------- m2f -------------------- > > Read this topic online here: > http://forums.zenoss.com/viewtopic.php?p=34791#34791 > > -------------------- m2f -------------------- > > > > _______________________________________________ > zenoss-users mailing list > [email protected] > http://lists.zenoss.org/mailman/listinfo/zenoss-users _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users