Hello,

I'm testing the latest pixma support against the TS6150 which is listed as
not yet tested.

I can't connect over USB or TCP even if I explicitly place my device's IP
address in /etc/sane.d/pixma.conf as follows:-

bjnp-timeout=5000
bjnp://192.168.0.100:8612

I am running on Ubuntu 18.04.1 and have built from the latest source in
master branch of https://gitlab.com/sane-project/backends.

The compilation is with debug and I get the following output pasted below.

The device is working since I am able to scan in an incredibly limited
fashion using the official scangearmp2 (which I have since uninstalled).
The device also works if I reboot to windows.

----------------------------------------------
giles@gklinux:~/github/backends$ SANE_DEBUG_PIXMA=21 SANE_DEBUG_BJNP=3
simple-scan

(simple-scan:15264): Gtk-WARNING **: 17:10:07.715: Failed to register
client: GDBus.Error:org.gnome.SessionManager.AlreadyRegistered: Unable to
register client
[sanei_debug] Setting debug level of pixma to 21.
[pixma] pixma is compiled with pthread support.
[pixma] pixma version 0.17.49
[sanei_debug] Setting debug level of bjnp to 3.
[bjnp] sanei_bjnp_find_devices, pixma backend version: 0.17.49
[bjnp] Set new default timeout value: 5000 ms.[bjnp]
sanei_bjnp_find_devices: Adding scanner from pixma.conf: bjnp://
192.168.0.100:8612
[bjnp] bjnp_allocate_device(bjnp://192.168.0.100:8612/timeout=5000) 0
[bjnp] get_scanner_name: Name for 192.168.0.100 not found : Name or service
not known
[bjnp] setup_udp_socket: Setting up a UDP socket, dest: 192.168.0.100  port
8612
[bjnp] udp_command: ERROR - recv failed: Connection refused[bjnp]
udp_command: ERROR - recv failed: Connection refused[bjnp] udp_command:
ERROR - recv failed: Connection refused[bjnp] udp_command: ERROR - no data
received (timeout = 5000)
[bjnp] bjnp_init_device_structure: Cannot read mac address, skipping this
scanner
[bjnp] bjnp_allocate_device: Scanner not yet in our list, added it:
192.168.0.100:8612
[bjnp] setup_udp_socket: Setting up a UDP socket, dest: 192.168.0.100  port
8612
[bjnp] udp_command: ERROR - recv failed: Connection refused[bjnp]
udp_command: ERROR - recv failed: Connection refused[bjnp] udp_command:
ERROR - recv failed: Connection refused[bjnp] udp_command: ERROR - no data
received (timeout = 5000)
[bjnp] get_scanner_id: ERROR - Failed to retrieve scanner identity:
[bjnp] add_scanner: ERROR - Cannot read scanner make & model: bjnp://
192.168.0.100:8612/timeout=5000
[bjnp] sanei_bjnp_find_devices: Added all configured scanners, now do auto
detection...
[bjnp] prepare_socket: lo is not a valid IPv4 interface, skipping...
[bjnp] prepare_socket: eno1 is IPv4 capable, sending broadcast, socket = 50
[bjnp] prepare_socket: lo is not a valid IPv6 interface, skipping...
[bjnp] prepare_socket: eno1 is IPv6 capable, sending broadcast, socket = 51
[bjnp] prepare_socket: eno1 is IPv6 capable, sending broadcast, socket = 52
[bjnp] prepare_socket: eno1 is IPv6 capable, sending broadcast, socket = 53
[bjnp] sanei_find_devices: scanner discovery finished...
[pixma] pixma_find_scanners() found 0 devices
-- 