On Tue, Nov 16, 2010 at 5:43 PM, David Leimbach <leim...@gmail.com> wrote:
> I'm trying to figure out how to correctly sync a plan9port venti instance so
> I can start it back up again and have it actually function :-).
> using venti/sync doesn't appear to get the job done...

It should.  Not using venti/sync should work too since
vac etc all sync before hanging up.  The flushicache/flushdcache
trick will make restarting a little faster, but it should not
be necessary for correctness and shouldn't even be
that much faster.

Russ