On 2009-12-10, at 10:32 AM, Nagykaldi, Zsolt F. (HSC) wrote:
Has any of you seen this behavior? Solutions?
When the AG venue client (v3.2) enters a venue on a Win 7 machine, it hangs
when it tries to pull up vic and rat and then crashes: "pythonw.exe has stopped
working - prob event name: appcrash". I am running the client under Win XP SP3
compatibility and already added C:\Python24 to the path.
Try this: After you launch AG, but before you attempt to connect to a node,
Choose Tools->Preferences. On the Preferences Network tab, deselect the "Run
integrated multicast beacon client" option. Save, close, enjoy.
Not sure what the problem is, but on both Vista and Win 7 running the AG 3.2
beta I always need to do this.