Sam, We had a similar problem. The library reconfigure itself every time you have had the door open, it reads some barcode labels internally that tells it what HW is installed and the barcode could be dirty/destroyed such that it isn't aware of the magazines in the door. HW support should be able to fix it (they had to replace parts in it for us). Regards, Jan Norback Tivoli Certified Consultant: ADSM/TSM IBM Cert. Adv. Technical Expert RS/6000 AIX Atos Origin-IT (MS/DS/OSS Unix) VA-106, PO-box 218, 5600 MD Eindhoven, The Netherlands Groenewoudseweg 1 5621 BA Eindhoven, The Netherlands Email: [EMAIL PROTECTED] Tel: +31 (0)40-2780289 Mobile: +31 (0)6-12994492 Fax : +31 40 2783962
-----Original Message----- From: Sam Schrage [mailto:[EMAIL PROTECTED]] Sent: Thursday, February 28, 2002 4:23 PM To: [EMAIL PROTECTED] Subject: 3583 LTO problems Any one have a problem with TSM auditing a LTO 3583 library. Some of my tapes are missing but when I open the door of the library I see all the tape slots full. I use the I/O door to input tapes only as SCRATCH so all tapes in the library should be known to TSM as SCRATCH or PRIVATE. When the 3583 reinitializes after the door is open sometime it sees the magazines in the door...sometimes not. I think it's more a hardware problem than TSM...until the hardware sees the tapes correctly TSM won't. Any ideas. Call has been logged to hardware support. Sam Schrage TRW Systems 615-360-4716