Sam,
We had a similar problem.
The library reconfigure itself every time you have had the door open, it
reads some barcode labels internally that tells it what HW is installed and
the barcode could be dirty/destroyed such that it isn't aware of the
magazines in the door. HW support should be able to fix it (they had to
replace parts in it for us).
Regards,
Jan Norback
Tivoli Certified Consultant: ADSM/TSM
IBM Cert. Adv. Technical Expert RS/6000 AIX
Atos Origin-IT (MS/DS/OSS Unix)
VA-106, PO-box 218, 5600 MD Eindhoven, The Netherlands
Groenewoudseweg 1 5621 BA Eindhoven, The Netherlands
Email: [EMAIL PROTECTED]
Tel: +31 (0)40-2780289
Mobile: +31 (0)6-12994492
Fax     : +31 40 2783962


-----Original Message-----
From: Sam Schrage [mailto:[EMAIL PROTECTED]]
Sent: Thursday, February 28, 2002 4:23 PM
To: [EMAIL PROTECTED]
Subject: 3583 LTO problems


Any one have a problem with TSM auditing a LTO 3583 library.   Some of my
tapes
are missing but when I open the door of the library I see all the tape slots
full.   I use the I/O door to input tapes only as SCRATCH so all tapes in
the
library should be known to TSM as SCRATCH or PRIVATE.

When the 3583  reinitializes after the door is open sometime it sees the
magazines in the door...sometimes not.   I think it's more a hardware
problem
than TSM...until the hardware sees the tapes correctly TSM won't.

Any ideas.   Call has been logged to hardware support.


Sam Schrage
TRW Systems
615-360-4716

Reply via email to