Just an update...
I had already tried auditing the library with checklabel=barcode for a first fix attempt and still saw the error. Yesterday afternoon working with ADIC tech support we ran an "inventory process from the library side" and then reran the audit on TSM server checklabel=barcode....and no errors after that. (fingers crossed) Nancy Backhaus Enterprise Systems HealthNow, NY 716-887-7979 Zoltan Forray/AC/VCU <[EMAIL PROTECTED]> Sent by: "ADSM: Dist Stor Manager" <ADSM-L@VM.MARIST.EDU> 04/10/2006 04:39 PM Please respond to "ADSM: Dist Stor Manager" To: ADSM-L@VM.MARIST.EDU cc: Subject: Re: ANR8300E - I/O error on library desc= the destination slot or drive was full in an attemt to move a volume Been there - Done that. Seen it numerous times. Just perform an audit of your library, scanning the barcodes. There is an out-of-sync problem in the library inventory (internal). There is a tape who's barcode it didn't read during the last scan pass or you had some kind of library error. In fact, I just did one......................................... AUDIT LIBR <insert your library name here> checkl=b Nancy L Backhaus <[EMAIL PROTECTED]> Sent by: "ADSM: Dist Stor Manager" <ADSM-L@VM.MARIST.EDU> 04/10/2006 03:15 PM Please respond to "ADSM: Dist Stor Manager" <ADSM-L@VM.MARIST.EDU> To ADSM-L@VM.MARIST.EDU cc Subject [ADSM-L] ANR8300E - I/O error on library desc= the destination slot or drive was full in an attemt to move a volume Anyone see this error below? Looking for direction/suggestions? The tape(s) do actually does dismount. The issue is occurring on different drives. All volumes are online, no unavail, no damaged, etc. I audited the library, it was a successful audit checklabel=barcode. **Background - Updated a week ago Library firmware from 3.1 to 4.1 and then backed out the library firmware code because internal barcode on the tapes could not be read. So we went back to our 3.1 firmware and thought we were ok again. Also, a couple other ADIC clients reported similiar issues with new firmware. Then we started seeing this error today with TSM sense data. Errpt - showing nothing Only TSM is reporting error, the library and aix are reporting no errors. Version: TSM Version - 5.3.2.2 AIX - 5.3 Mod 3 ADIC I2000 Scalar Library(LTO 2 drives), LTO2 tapes actlog: 04/10/06 13:16:44 ANR8300E I/O error on library BLUE (OP=00006C03, CC=315, KEY=05, ASC=3B, ASCQ=0D, SENSE=70.00.05.00.00.00.00.0A.0- 0.00.00.00.3B.0D.00.CF.00.06., Description=The destination slot or drive was full in an attempt to move a volume). Refer to Appendix D in the 'Messages' manual for recommended action. (PROCESS: 302) 04/10/06 13:16:44 ANR8469E Dismount of LTO volume TS1430 from drive DRIVE13 (/dev/rmt13) in library BLUE01 failed. (PROCESS: 302) Sense Data= Key (05) = illegal request CC(315)= dest slot was full ASC=3B, ASCQ=OD = medium destination element is full Nancy Backhaus Enterprise Systems HealthNow, NY 716-887-7979 CONFIDENTIALITY NOTICE: This email message and any attachments are for the sole use of the intended recipient(s) and may contain proprietary, confidential, trade secret or privileged information. Any unauthorized review, use, disclosure or distribution is prohibited and may be a violation of law. If you are not the intended recipient or a person responsible for delivering this message to an intended recipient, please contact the sender by reply email and destroy all copies of the original message.