Review your TSM server and see if the machine is associated with multiple schedules.
-----Original Message----- From: ADSM: Dist Stor Manager [mailto:[EMAIL PROTECTED] On Behalf Of Kerry Campbell Sent: Wednesday, December 20, 2006 9:29 AM To: ADSM-L@VM.MARIST.EDU Subject: I have experienced a "missed" backup and reviewed the DSMSCHED.log file on the machine that missed the backup. However, after reviewing the log file, I am still puzzled. It looks like it was skipped because some other process was running in the background. Nothing has changed on the machine and no schedule changes have occurred. I have included part of the messages from the log file below. As always, any help is appreciated. Thanks, Kerry 12/19/06 13:15:22 --- SCHEDULEREC QUERY BEGIN 12/19/06 13:15:22 --- SCHEDULEREC QUERY END 12/19/06 13:15:22 Next operation scheduled: 12/19/06 13:15:22 ------------------------------------------------------------ 12/19/06 13:15:22 Schedule Name: TOTAL_SYSTEM 12/19/06 13:15:22 Action: Incremental 12/19/06 13:15:22 Objects: 12/19/06 13:15:22 Options: -subdir=yes 12/19/06 13:15:22 Server Window Start: 01:00:00 on 12/20/06 12/19/06 13:15:22 ------------------------------------------------------------ 12/19/06 13:15:22 Scheduler has been stopped. 12/19/06 23:13:35 Scheduler has been started by Dsmcad. 12/19/06 23:13:35 Querying server for next scheduled event. 12/19/06 23:13:35 Node Name: LPAR188 12/19/06 23:13:35 ANS2050E TSM needs to prompt for the password but cannot prompt because the process is running in the background. 12/19/06 23:13:35 ANS2050E TSM needs to prompt for the password but cannot prompt because the process is running in the background. *** CONFIDENTIALITY NOTICE*** This message and any included attachments are from MedSynergies, Inc. and are intended only for the addressee. The contents in this message contain confidential information belonging to the sender that is legally protected. Unauthorized forwarding, printing, copying, distribution, or use of such information is strictly prohibited and may be unlawful. If you are not the addressee, please promptly delete this message and notify the sender of the delivery error by e-mail or contact MedSynergies, Inc. at [EMAIL PROTECTED]