so, i'm 99% sure we use a netonix to power ours and they're 24 v ----- Original Message ----- From: Josh Luthman To: Josh Baird Cc: af@af.afmug.com Sent: Thursday, June 21, 2018 11:39 AM Subject: Re: [AFMUG] ePMP voltages again - specifically 2ghz
Except for every single Ubnt device and a majority of Mikrotiks.... Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Thu, Jun 21, 2018 at 12:39 PM, Josh Baird <joshba...@gmail.com> wrote: I promise life will be easier if you just use 48V. :) On Thu, Jun 21, 2018 at 12:35 PM, Josh Luthman <j...@imaginenetworksllc.com> wrote: I'm trying to use a Powerbox Pro to power up two epmp APs. The 5 GHz is just fine but the 2 GHz is saying current too low. Both ports are getting 23 volts and the cables are <10 feet (from the Powerbox Pro). Does anyone know if the 2ghz requires more voltage possibly? Spec sheet does say 23 volts min but it's weird one powers (5 ghz) and the other doesn't. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 -- AF mailing list AF@af.afmug.com http://af.afmug.com/mailman/listinfo/af_af.afmug.com ------------------------------------------------------------------------------ -- AF mailing list AF@af.afmug.com http://af.afmug.com/mailman/listinfo/af_af.afmug.com
-- AF mailing list AF@af.afmug.com http://af.afmug.com/mailman/listinfo/af_af.afmug.com