The Base 3 gets calibrated before it leaves the shop. The base 2 isn't calibrated at all and relies on the precision of the components in it.
If this is a Base 3, it might need a recalibration, but we don't currently have a way to do this in the field. Shoot us an email to cust...@packetflux.com On the Base 2, it might end up being a damaged component. On Fri, Jun 4, 2021 at 12:42 PM Sam Lambie <samtaos...@gmail.com> wrote: > I monitor battery voltage on the 2nd power port of Site Monitors when > power goes down, I can then take a look at the voltage and determine > whether I need to lug out the genny or not. But, one particular site > monitor reads 24.5 but my multi meter measures 25.1 at the same terminals. > > So far I don't see a way to edit the values. It won't take when I hit the > pencil. > > -- > -- > *Sam Lambie* > Taosnet Wireless Tech. > 575-758-7598 Office > www.Taosnet.com <http://www.newmex.com> > -- > AF mailing list > AF@af.afmug.com > http://af.afmug.com/mailman/listinfo/af_af.afmug.com > -- - Forrest
-- AF mailing list AF@af.afmug.com http://af.afmug.com/mailman/listinfo/af_af.afmug.com