So it seems at least one AP power cycled on its own.  Does this mean the
second sync injector is bad?  Fuse has not popped and all the radios are
having problems with some combination of link, sync and power.

Is there any other possibility?

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Dec 8, 2014 5:02 PM, "Josh Luthman" <j...@imaginenetworksllc.com> wrote:

> GigE Packetflux SyncInjector.  I replaced it thinking it was bad earlier
> today, but now I'm not sure it was necessary.
>
> There are 4x APs here.  What I have labeled as ap8 has 0 problems.  Now
> ap7 seems to work roughly 95% of the ping (based on pings).  Ap6 works
> roughly 83%.  Ap5 won't even power on (thinking bad AP or the cable itself,
> another AP powered on using that port - this is tomorrows task).
>
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
> On Mon, Dec 8, 2014 at 4:56 PM, Nate Burke via Af <af@afmug.com> wrote:
>
>> What POE are you using?
>>
>>
>>
>> On 12/8/2014 3:55 PM, Josh Luthman via Af wrote:
>>
>>> Has anyone had problems with this?  I'm running into all kinds of weird
>>> issues where an AP will work for a while, then link up/down forever.  I
>>> can't find any kind of pattern with it and I'm starting to wonder if
>>> there's an expected problem (bug/compatibility) with these ports. Currently
>>> on 6.22 ROS.
>>>
>>> Josh Luthman
>>> Office: 937-552-2340
>>> Direct: 937-552-2343
>>> 1100 Wayne St
>>> Suite 1337
>>> Troy, OH 45373
>>>
>>
>>
>

Reply via email to