The only thing a fuse protects against, when properly sized and installed,
is a short circuit event. They should never be viewed as some kind of surge
protection unless you enjoy being disappointed.

On Wed, Aug 19, 2015 at 11:46 AM, Jaime Solorza <losguyswirel...@gmail.com>
wrote:

> Fast is better for protection.    Better than old cigarette pack method
> used on Fender and Marshall amps back in the day
> On Aug 19, 2015 7:47 AM, "Ken Hohhof" <af...@kwisp.com> wrote:
>
>> I use fast blow 5x20 mm fuses for radios and other electronics, but
>> recently became aware that medium blow fuses exist.  Not widely available,
>> but examples are Belfuse 530-5MT and Littelfuse 233 series.
>>
>> So is anyone using these?  Any advantage?  I'm thinking devices that
>> might have enough inrush current to blow a fast blow fuse, although that
>> hasn't been a problem so far.
>>
>>


-- 
Lewis Bergman
325-439-0533 Cell

Reply via email to