Netonix switches have been great for us.  We're using the DC model
with a few batteries for backup.  The Netonix takes 9-60 VDC in and
can output 24V or 48V (configurable by port).  Perfect for powering a
24V Mikrotik and a few 48V radios.

-Rob



On Wed, May 4, 2016 at 3:02 PM, Christopher Gray
<cg...@graytechsoftware.com> wrote:
> For my routed 100 Mbps micro repeater sites I've been running MikroTik
> RB750P routers for both routing traffic and powering radios (With good
> results).
>
> I want to setup my first small routed 1 Gbps repeater site using 2x B5
> backhaul links and 1x A5 PtMP. What are others using to run a small routed
> site that runs 48V Gigabit radios?
>
> I'm considering a RB750G with a Netonix WS-6-MINI, but using a Netonix as a
> power injector seems a little overkill.

Reply via email to