The only time I have really seen the need is the larger diameter cable helps with longer runs of cable especially with POE. As others have said though I am starting especially on backhaul to do all fiber. It is cheaper easier to weatherproof. If it gets water in the jacket and you have it spliced and terminated outside your cabinet then water drains out. Plus you don't have to worry about blown router/switch ports anymore.

I prefer the Primus Cable Cat6 they also have connectors that are a great deal like UBNT ones and have a special insert that lines the wires up to the pins.

Trey

On 8/2/2016 12:25 PM, Mike Hammett wrote:
Agreed. I'm just using ToughCable until the gear I use starts accepting
SFPs.



-----
Mike Hammett
Intelligent Computing Solutions <http://www.ics-il.com/>
<https://www.facebook.com/ICSIL><https://plus.google.com/+IntelligentComputingSolutionsDeKalb><https://www.linkedin.com/company/intelligent-computing-solutions><https://twitter.com/ICSIL>
Midwest Internet Exchange <http://www.midwest-ix.com/>
<https://www.facebook.com/mdwestix><https://www.linkedin.com/company/midwest-internet-exchange><https://twitter.com/mdwestix>
The Brothers WISP <http://www.thebrotherswisp.com/>
<https://www.facebook.com/thebrotherswisp>


<https://www.youtube.com/channel/UCXSdfxQv7SpoRQYNyLwntZg>
------------------------------------------------------------------------
*From: *"Josh Reynolds" <[email protected]>
*To: *[email protected]
*Sent: *Monday, July 25, 2016 12:57:51 PM
*Subject: *Re: [AFMUG] Anyone Installing Cat6 / really thick Cat5e?

Cat6/a has some nice anti-crosstalk features for large trays of cables
(48 port switch or more, hundreds of runs, etc). Can also help with near
end crosstalk. Can also help with POE if you're used to shitty cat5/e
with small gauge wire. Also is good for short 10G runs.

That said, most WISPs aren't in any of those situations, and if you are
and it's possible, fiber is often a much better solution.

TLDR: stick to tough cable or similar


On Jul 25, 2016 12:54 PM, "Christopher Gray" <[email protected]
<mailto:[email protected]>> wrote:

    I just picked up some Shireen DC-2021 Cat6 cable, thinking I would
    start using Cat6 for my Mimosa installations (as suggested).

    It turns out, the individual insulation is too big for any of my
    RJ45 ends, and the jacket is also too big. Now, I'm looking at Cat6A
    connectors (that have a staggered insert and a full shield). Next, I
    will need a new crimper that does not crush the shield on the Cat6A
    connector.

    Anyhow, it seems like a lot of work to use Cat6 where some
    ToughCable and basic shielded RJ45 connectors might be functionally
    equivalent.


    Should I be seriously considering Cat6? When did you decide Cat6 was
    worth it?

    -Chris





Reply via email to