I'm pretty sure we have several airfibers running on them with sync on - I usually try to turn it off, but I haven't noticed any problems, and it certainly won't be smoking or anything like that.
On Tue, Nov 22, 2016 at 10:19 AM, That One Guy /sarcasm < thatoneguyst...@gmail.com> wrote: > would be neat to do it and look at the pair report on the af, just to see > what it looks like, assuming the port isnt smoking > > having the site monitor at every site is really a decent deal, for 99 > bucks you get a temperature probe, a couple power monitors and a couple > relays that are all IP controlled, theyre worth putting in even without > syncinjectors imho > with them you get a crap ton more versatility out of the injectors too > > On Tue, Nov 22, 2016 at 9:43 AM, Kurt Fankhauser <lists.wavel...@gmail.com > > wrote: > >> Been using the injectors for 7 years without needing one yet. I'm not >> opposed to them though, Just looking for a quick solution fast here to >> power some Airfibers >> >> On Tue, Nov 22, 2016 at 10:39 AM, Josh Baird <joshba...@gmail.com> wrote: >> >>> You should really use SiteMonitors if you use SyncInjectors. It allows >>> you to manage and monitor the SyncInjector. >>> >>> On Tue, Nov 22, 2016 at 10:37 AM, Kurt Fankhauser < >>> lists.wavel...@gmail.com> wrote: >>> >>>> I just received my first powerinjector + sync today. If I want to power >>>> some Airfibers with these do I need to turn the sync off for those ports? I >>>> don't see a jumper to turn off sync, is it ok to provider sync on a port >>>> with an Airfiber? Does it hurt anything? It looks to me like the only way >>>> to turn off sync is buy the additional site monitor base thing to hookup to >>>> it and turn it off through the web interface? >>>> >>>> On Mon, Nov 21, 2016 at 2:39 PM, George Skorup <geo...@cbcast.com> >>>> wrote: >>>> >>>>> I have four 5GHz 450i's running on our office tower fed from a GigE >>>>> PowerInjector+Sync. They're running 14.1.2. They received sync shortly >>>>> after boot, DFS, etc. BTW, no GigE-APC's in line on these yet. I'm like >>>>> two >>>>> short at the moment. But we know that 1000Base-T and sync over power + the >>>>> older APC's don't play nice anyway. >>>>> >>>>> On 11/21/2016 1:23 PM, Mathew Howard wrote: >>>>> >>>>> I've had a couple of them where I wasn't getting sync and couldn't >>>>> figure out why... in one case (maybe both... I don't remember off hand), I >>>>> was getting sync to an ePMP, but not to a PMP450i 900mhz AP that were both >>>>> plugged into the same sync injector... I didn't really need sync on the >>>>> 900mhz at the time, so I just switched it to generate it's own timing, and >>>>> I haven't gotten around to trying to figure it out yet, but now I'm >>>>> wondering if it would eventually come up if I left it alone. >>>>> >>>>> On Mon, Nov 21, 2016 at 12:45 PM, Seth Mattinen <se...@rollernet.us> >>>>> wrote: >>>>> >>>>>> On 11/21/16 10:39, ch...@wbmfg.com wrote: >>>>>> >>>>>>> I had all the packet flux gear running for days, plugged in the 450i >>>>>>> and >>>>>>> started trying to figure out why it was not receiving sync. Half >>>>>>> hour >>>>>>> or more later it said it was OK, so the delay had to be Cambium, not >>>>>>> Packetflux. >>>>>>> >>>>>> >>>>>> >>>>>> Check if the packetflux says it has fix and 1PPS is active on the >>>>>> binary tab and that the used pulse count is increasing on the analog tab. >>>>>> >>>>>> ~Seth >>>>>> >>>>> >>>>> >>>>> >>>> >>> >> > > > -- > If you only see yourself as part of the team but you don't see your team > as part of yourself you have already failed as part of the team. >