I'm pretty sure we have several airfibers running on them with sync on - I
usually try to turn it off, but I haven't noticed any problems, and it
certainly won't be smoking or anything like that.

On Tue, Nov 22, 2016 at 10:19 AM, That One Guy /sarcasm <
thatoneguyst...@gmail.com> wrote:

> would be neat to do it and look at the pair report on the af, just to see
> what it looks like, assuming the port isnt smoking
>
> having the site monitor at every site is really a decent deal, for 99
> bucks you get a temperature probe, a couple power monitors and a couple
> relays that are all IP controlled, theyre worth putting in even without
> syncinjectors imho
> with them you get a crap ton more versatility out of the injectors too
>
> On Tue, Nov 22, 2016 at 9:43 AM, Kurt Fankhauser <lists.wavel...@gmail.com
> > wrote:
>
>> Been using the injectors for 7 years without needing one yet. I'm not
>> opposed to them though, Just looking for a quick solution fast here to
>> power some Airfibers
>>
>> On Tue, Nov 22, 2016 at 10:39 AM, Josh Baird <joshba...@gmail.com> wrote:
>>
>>> You should really use SiteMonitors if you use SyncInjectors.  It allows
>>> you to manage and monitor the SyncInjector.
>>>
>>> On Tue, Nov 22, 2016 at 10:37 AM, Kurt Fankhauser <
>>> lists.wavel...@gmail.com> wrote:
>>>
>>>> I just received my first powerinjector + sync today. If I want to power
>>>> some Airfibers with these do I need to turn the sync off for those ports? I
>>>> don't see a jumper to turn off sync, is it ok to provider sync on a port
>>>> with an Airfiber? Does it hurt anything? It looks to me like the only way
>>>> to turn off sync is buy the additional site monitor base thing to hookup to
>>>> it and turn it off through the web interface?
>>>>
>>>> On Mon, Nov 21, 2016 at 2:39 PM, George Skorup <geo...@cbcast.com>
>>>> wrote:
>>>>
>>>>> I have four 5GHz 450i's running on our office tower fed from a GigE
>>>>> PowerInjector+Sync. They're running 14.1.2. They received sync shortly
>>>>> after boot, DFS, etc. BTW, no GigE-APC's in line on these yet. I'm like 
>>>>> two
>>>>> short at the moment. But we know that 1000Base-T and sync over power + the
>>>>> older APC's don't play nice anyway.
>>>>>
>>>>> On 11/21/2016 1:23 PM, Mathew Howard wrote:
>>>>>
>>>>> I've had a couple of them where I wasn't getting sync and couldn't
>>>>> figure out why... in one case (maybe both... I don't remember off hand), I
>>>>> was getting sync to an ePMP, but not to a PMP450i 900mhz AP that were both
>>>>> plugged into the same sync injector... I didn't really need sync on the
>>>>> 900mhz at the time, so I just switched it to generate it's own timing, and
>>>>> I haven't gotten around to trying to figure it out yet, but now I'm
>>>>> wondering if it would eventually come up if I left it alone.
>>>>>
>>>>> On Mon, Nov 21, 2016 at 12:45 PM, Seth Mattinen <se...@rollernet.us>
>>>>> wrote:
>>>>>
>>>>>> On 11/21/16 10:39, ch...@wbmfg.com wrote:
>>>>>>
>>>>>>> I had all the packet flux gear running for days, plugged in the 450i
>>>>>>> and
>>>>>>> started trying to figure out why it was not receiving sync.  Half
>>>>>>> hour
>>>>>>> or more later it said it was OK, so the delay had to be Cambium, not
>>>>>>> Packetflux.
>>>>>>>
>>>>>>
>>>>>>
>>>>>> Check if the packetflux says it has fix and 1PPS is active on the
>>>>>> binary tab and that the used pulse count is increasing on the analog tab.
>>>>>>
>>>>>> ~Seth
>>>>>>
>>>>>
>>>>>
>>>>>
>>>>
>>>
>>
>
>
> --
> If you only see yourself as part of the team but you don't see your team
> as part of yourself you have already failed as part of the team.
>

Reply via email to