I've been running some tests with Cold startup of EPMP1000 w/ sync Radios. Does the Internal heater only function with 4/5- 7/8+? A cold radio (18F) radio will power on but seems stuck in a reboot loop with 4/5+ 7/8- The same radio powered on and booted within 2 minutes or so with 4/5- 7/8+

Power draw with 4/5+ 7/8- was around 4w, and would randomly spike to around 15w The power light would stay on, but sync and ethernet lights would go on and off, like it was continually rebooting.

Power draw with 4/5- 7/8+ was a solid 15w for about 2 minutes with only the power light on, then 4w once booted.

I just presumed that since it would power on with both polarities, the heater would work with both polarities as well. It's looking like that might not be the case.