We have a tower using the same AF5x frequency (both Masters - I'll call them 
BHM-1 and BHM2) going about 180 deg. Different directions with about 30 ft. of 
vertical separation.   About 2 miles away is the "slave side" (I'll call in 
BHS2) of one of these on a building, and I want another AFX5 dish going almost 
180 degrees to this slave going to another tower 1.5 miles away. I can get 
about 15 ft. separation F/B between BHS2 and this new dish.  Can I use the same 
frequency again on this new link?   If I so I would assume I make the new "back 
to back - 15 ft. apart AF5x also be a slave and the far end (new tower) be the 
master?

Since they are all GPS synced  I didn't know how much difference it makes or 
are there additional considerations?

Paul