We design for 50 subs at 8/2. Plans are 8/2, 16/4, 32/8 so a 16/4 would be two 8/2s and a 32/8 would be 4. Important thing to watch is frame utilization. Anything over 50 subs on a 450/450i tends to hit 90% + on DL frame utilization. We have our first 450M in the air and should be ready to move subs over to it as soon as I figure out whats going on with the SFP interface.
On Fri, Aug 25, 2017 at 5:38 PM, Andreas Wiatowski <andr...@silowireless.com > wrote: > Hi all, > > I am rather curious to see how many subscribers you are putting on a 450 > 5GHz AP in a 20 MHz channel. We aim to provide on average a 10 to 25Mbps > experience to our subscriber base and we seem to max out at 25 to 30 > subscribers per access point. I am wondering if we are running into an > issue with our control slots on our APs and maybe changing our control > slots from 3 to some other number might allow us to put more people on an > AP. > > Your comments are appreciated. > > Cheers, > > Andreas Wiatowski, CEO > Silo Wireless Inc. > 1-866-727-4238 x-600 > http://www.silowireless.com > Wireless | Fibre | VoIP | PBX | IPTV