Man My brain hurts just trying to wrap my head around the concepts of how to implement this. and I thought I could get away with using a raspberry pi to do it all..
On Wed, Aug 30, 2017 at 6:38 PM, Forrest Christian (List Account) < [email protected]> wrote: > Well, it certainly can't be less fun than I've been having over the last > few months. > > On Wed, Aug 30, 2017 at 2:44 PM, Chuck McCown <[email protected]> wrote: > >> What is the fun in that... >> >> *From:* Forrest Christian (List Account) >> *Sent:* Wednesday, August 30, 2017 2:25 PM >> *To:* af >> *Subject:* Re: [AFMUG] Cost effective battery charging and monitoring >> device >> >> But what if working is putting rackinjectors in boxes so I can actually >> get back to engineering solutions for this type of stuff? >> >> On Wed, Aug 30, 2017 at 11:51 AM, Chuck McCown <[email protected]> wrote: >> >>> Forrest, quit working and come out and play with us.... >>> >>> *From:* Chuck McCown >>> *Sent:* Wednesday, August 30, 2017 11:49 AM >>> *To:* [email protected] >>> *Subject:* Re: [AFMUG] Cost effective battery charging and monitoring >>> device >>> >>> But you can use a voltage divider to convert the 0-5 volt to 0-.1 volt. >>> Two resistors. >>> >>> *From:* George Skorup >>> *Sent:* Wednesday, August 30, 2017 11:48 AM >>> *To:* [email protected] >>> *Subject:* Re: [AFMUG] Cost effective battery charging and monitoring >>> device >>> >>> No, the SiteMonitor shunt input is ±100mV nominal. >>> >>> On 8/30/2017 12:42 PM, Jesse DuPont wrote: >>> >>> Would these work on a SiteMonitor? They output 1-5V DC based on current >>> flowing through. >>> >>> https://flexscada.com/product/hall-effect-current-sensor-ac-75a-dc-100a/ >>> >>> *Jesse DuPont* >>> >>> Network Architect >>> email: [email protected] >>> Celerity Networks LLC >>> >>> Celerity Broadband LLC >>> Like us! facebook.com/celeritynetworksllc >>> >>> Like us! facebook.com/celeritybroadband >>> On 8/30/17 11:29 AM, George Skorup wrote: >>> >>> Yeah, about that. I wouldn't use those on 12VDC systems. Too much >>> current. I've burned up a couple of the 10A shunts on Traco BCMUs that were >>> running around 200W load on battery. 200/13 = 15 amps. Ungood. One site at >>> about 225W, first time it went to battery, the shunt went kaput after 10-15 >>> minutes and the site went down. >>> >>> I'm hoping Forrest comes up with some Hall effect stuff or even plain >>> 20+ amp shunts that can be used on the SiteMonitor's existing 100mv input. >>> Hall effect is nice because you don't have to be "in" the circuit. But I'll >>> take what I can get. >>> >>> On 8/30/2017 10:26 AM, Adam Moffett wrote: >>> >>> Yeah, up to 10 amp. >>> >>> >>> ------ Original Message ------ >>> From: "Chuck McCown" <[email protected]> >>> To: [email protected] >>> Sent: 8/30/2017 11:18:36 AM >>> Subject: Re: [AFMUG] Cost effective battery charging and monitoring >>> device >>> >>> >>> I think Forrest has them on his site with the site monitors. >>> >>> *From:* Sam Lambie >>> *Sent:* Wednesday, August 30, 2017 9:15 AM >>> *To:* [email protected] >>> *Subject:* Re: [AFMUG] Cost effective battery charging and monitoring >>> device >>> >>> Parallel. Site Monitor! Now where can I get a shunt? >>> >>> On Wed, Aug 30, 2017 at 9:09 AM, Chuck McCown <[email protected]> wrote: >>> >>>> 4 batts in series or parallel? >>>> Shunt + sitemonitor would be a better way to go and you don’t have to >>>> write code. >>>> >>>> *From:* Sam Lambie >>>> *Sent:* Wednesday, August 30, 2017 9:06 AM >>>> *To:* [email protected] >>>> *Subject:* [AFMUG] Cost effective battery charging and monitoring >>>> device >>>> >>>> Hey all, >>>> I am getting away from using APC at a couple of our sites and right now >>>> I have installed a Tripp-Lite APS750 connected to 4 Deep cycle marine >>>> batteries for a total of 404 aH system. I'd like to be able to monitor the >>>> discharge rate of the batteries when power is out remotely. What have you >>>> guys been doing to that effect? >>>> >>>> I'm thinking a Pi and a shunt and some quick scripting classes on >>>> Python to put it all together... >>>> >>>> -- >>>> -- >>>> *Sam Lambie* >>>> Taosnet Wireless Tech. >>>> 575-758-7598 <%28575%29%20758-7598> Office >>>> www.Taosnet.com <http://www.newmex.com> >>>> >>> >>> >>> >>> -- >>> -- >>> *Sam Lambie* >>> Taosnet Wireless Tech. >>> 575-758-7598 <(575)%20758-7598> Office >>> www.Taosnet.com <http://www.newmex.com> >>> >>> >>> >>> >>> >> >> >> -- >> *Forrest Christian* *CEO**, PacketFlux Technologies, Inc.* >> Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602 >> [email protected] | http://www.packetflux.com >> <http://www.linkedin.com/in/fwchristian> >> <http://facebook.com/packetflux> <http://twitter.com/@packetflux> >> >> > > > -- > *Forrest Christian* *CEO**, PacketFlux Technologies, Inc.* > Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602 > [email protected] | http://www.packetflux.com > <http://www.linkedin.com/in/fwchristian> <http://facebook.com/packetflux> > <http://twitter.com/@packetflux> > > -- -- *Sam Lambie* Taosnet Wireless Tech. 575-758-7598 Office www.Taosnet.com <http://www.newmex.com>