Man My brain hurts just trying to wrap my head around the concepts of how
to implement this. and I thought I could get away with using a raspberry pi
to do it all..

On Wed, Aug 30, 2017 at 6:38 PM, Forrest Christian (List Account) <
[email protected]> wrote:

> Well, it certainly can't be less fun than I've been having over the last
> few months.
>
> On Wed, Aug 30, 2017 at 2:44 PM, Chuck McCown <[email protected]> wrote:
>
>> What is the fun in that...
>>
>> *From:* Forrest Christian (List Account)
>> *Sent:* Wednesday, August 30, 2017 2:25 PM
>> *To:* af
>> *Subject:* Re: [AFMUG] Cost effective battery charging and monitoring
>> device
>>
>> But what if working is putting rackinjectors in boxes so I can actually
>> get back to engineering solutions for this type of stuff?
>>
>> On Wed, Aug 30, 2017 at 11:51 AM, Chuck McCown <[email protected]> wrote:
>>
>>> Forrest, quit working and come out and play with us....
>>>
>>> *From:* Chuck McCown
>>> *Sent:* Wednesday, August 30, 2017 11:49 AM
>>> *To:* [email protected]
>>> *Subject:* Re: [AFMUG] Cost effective battery charging and monitoring
>>> device
>>>
>>> But you can use a voltage divider to convert the 0-5 volt to 0-.1 volt.
>>> Two resistors.
>>>
>>> *From:* George Skorup
>>> *Sent:* Wednesday, August 30, 2017 11:48 AM
>>> *To:* [email protected]
>>> *Subject:* Re: [AFMUG] Cost effective battery charging and monitoring
>>> device
>>>
>>> No, the SiteMonitor shunt input is ±100mV nominal.
>>>
>>> On 8/30/2017 12:42 PM, Jesse DuPont wrote:
>>>
>>> Would these work on a SiteMonitor? They output 1-5V DC based on current
>>> flowing through.
>>>
>>> https://flexscada.com/product/hall-effect-current-sensor-ac-75a-dc-100a/
>>>
>>> *Jesse DuPont*
>>>
>>> Network Architect
>>> email: [email protected]
>>> Celerity Networks LLC
>>>
>>> Celerity Broadband LLC
>>> Like us! facebook.com/celeritynetworksllc
>>>
>>> Like us! facebook.com/celeritybroadband
>>> On 8/30/17 11:29 AM, George Skorup wrote:
>>>
>>> Yeah, about that. I wouldn't use those on 12VDC systems. Too much
>>> current. I've burned up a couple of the 10A shunts on Traco BCMUs that were
>>> running around 200W load on battery. 200/13 = 15 amps. Ungood. One site at
>>> about 225W, first time it went to battery, the shunt went kaput after 10-15
>>> minutes and the site went down.
>>>
>>> I'm hoping Forrest comes up with some Hall effect stuff or even plain
>>> 20+ amp shunts that can be used on the SiteMonitor's existing 100mv input.
>>> Hall effect is nice because you don't have to be "in" the circuit. But I'll
>>> take what I can get.
>>>
>>> On 8/30/2017 10:26 AM, Adam Moffett wrote:
>>>
>>> Yeah, up to 10 amp.
>>>
>>>
>>> ------ Original Message ------
>>> From: "Chuck McCown" <[email protected]>
>>> To: [email protected]
>>> Sent: 8/30/2017 11:18:36 AM
>>> Subject: Re: [AFMUG] Cost effective battery charging and monitoring
>>> device
>>>
>>>
>>> I think Forrest has them on his site with the site monitors.
>>>
>>> *From:* Sam Lambie
>>> *Sent:* Wednesday, August 30, 2017 9:15 AM
>>> *To:* [email protected]
>>> *Subject:* Re: [AFMUG] Cost effective battery charging and monitoring
>>> device
>>>
>>> Parallel. Site Monitor! Now where can I get a shunt?
>>>
>>> On Wed, Aug 30, 2017 at 9:09 AM, Chuck McCown <[email protected]> wrote:
>>>
>>>> 4 batts in series or parallel?
>>>> Shunt + sitemonitor would be a better way to go and you don’t have to
>>>> write code.
>>>>
>>>> *From:* Sam Lambie
>>>> *Sent:* Wednesday, August 30, 2017 9:06 AM
>>>> *To:* [email protected]
>>>> *Subject:* [AFMUG] Cost effective battery charging and monitoring
>>>> device
>>>>
>>>> Hey all,
>>>> I am getting away from using APC at a couple of our sites and right now
>>>> I have installed a Tripp-Lite APS750 connected to 4 Deep cycle marine
>>>> batteries for a total of 404 aH system. I'd like to be able to monitor the
>>>> discharge rate of the batteries when power is out remotely. What have you
>>>> guys been doing to that effect?
>>>>
>>>> I'm thinking a Pi and a shunt and some quick scripting classes on
>>>> Python to put it all together...
>>>>
>>>> --
>>>> --
>>>> *Sam Lambie*
>>>> Taosnet Wireless Tech.
>>>> 575-758-7598 <%28575%29%20758-7598> Office
>>>> www.Taosnet.com <http://www.newmex.com>
>>>>
>>>
>>>
>>>
>>> --
>>> --
>>> *Sam Lambie*
>>> Taosnet Wireless Tech.
>>> 575-758-7598 <(575)%20758-7598> Office
>>> www.Taosnet.com <http://www.newmex.com>
>>>
>>>
>>>
>>>
>>>
>>
>>
>> --
>> *Forrest Christian* *CEO**, PacketFlux Technologies, Inc.*
>> Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602
>> [email protected] | http://www.packetflux.com
>> <http://www.linkedin.com/in/fwchristian>
>> <http://facebook.com/packetflux>  <http://twitter.com/@packetflux>
>>
>>
>
>
> --
> *Forrest Christian* *CEO**, PacketFlux Technologies, Inc.*
> Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602
> [email protected] | http://www.packetflux.com
> <http://www.linkedin.com/in/fwchristian>  <http://facebook.com/packetflux>
>   <http://twitter.com/@packetflux>
>
>


-- 
-- 
*Sam Lambie*
Taosnet Wireless Tech.
575-758-7598 Office
www.Taosnet.com <http://www.newmex.com>

Reply via email to