I thought about using a second cat5 for power, but I had some 14/2, so I
used that... but 14 guage really seems like overkill to me.

On Oct 23, 2017 8:56 PM, "George Skorup" <george.sko...@cbcast.com> wrote:

> Two cat5's. One obviously to the data/WAN port. The other, two pairs
> positive, two pairs negative. Nothing else. We did try a GigE-POE-SS (top)
> and GigE-POE-APC (bottom). Power worked fine, but couldn't get the
> etherlink link to come up. It was about 290 feet of cable. The eNBs have
> built-in SS on the data port, so possibly too much loss or something with
> the MTC suppressors added in.
>
> The new eNB coming out will have a standard terminal block and two SFP
> slots. I'm planning to use the Shireen DFP-1246 with that.
>
> On 10/23/2017 8:36 PM, Josh Baird wrote:
>
>> Those of you who have Baicells deployed, how are you powering the base
>> station?
>>
>> Are you running something like 14/2 up the tower and providing -/+48VDC
>> directly?
>>
>> Ugh - I thought the eNB had SFP's, but it looks like I need to provide
>> data over CAT5/6?
>>
>>
>>
>