you want six cables in one hole or 6 holes? 1/2 inch glands is what i use on single cables, available at any hardware store, they have like 3/4" thread, so the lock nut would affix. Theyre cheaper in bulk than a hardware store, like 6 for 30 bucks at hardware store or 50 for 100 bucks in bulk online
On Fri, May 25, 2018 at 3:48 PM, Bill Prince <part15...@gmail.com> wrote: > A 1" conduit bulkhead connector will do the trick. Attach a short length > of conduit on the outside with a sweep. > > If the nipple on the bulkhead connector is not long enough, you can get > longer nipples at any hardware store (1" though 3 or 4 inches). > > bp > <part15sbs{at}gmail{dot}com> > > > On 5/25/2018 1:43 PM, Mike Davis wrote: > > Any suggestions on where to get a cable wall pass-through for a 1/2" steel > plate? I am out of ideas of where to try. I need to get 6 cat cables from > the inside of a water tower to the outside at the top of the tower. > -- > *Mike Davis* > General Manager > Office: 260-349-1799 > Email: *mikeda...@allianceinternet.net <mikeda...@allianceinternet.net>* > > *Alliance Internet Communications* | www.allianceinternet.net > PO Box 1100 | 1220 South Wayne Street | Angola, IN | 46703 > <https://maps.google.com/?q=1220+South+Wayne+Street+%7C+Angola,+IN+%7C+46703&entry=gmail&source=g> > | 260-349-1799 > > > >